Details of steel structure architectural design

Time:[2021-7-10]  Hits:2432

Many details need to be considered in the design of steel structure buildings, such as appropriate structural damping ratio, rigid column base design, beam column rigid connection design, floor design, etc. The details of steel structure architectural design are discussed in detail.

1. Suitable structural damping ratio

In the overall calculation of steel structure building, especially according to the requirements of seismic code, it is very necessary to choose the appropriate structural damping ratio. Unless otherwise specified, the damping ratio of building structure should be 0.05. Because different steel structures have different seismic influence coefficients, the selection of damping ratio should be based on the proportion of materials. Generally speaking, the more flexible the overall stiffness of the structure, the lower the damping ratio.

2. Rigid column base design

The commonly used column bases of steel structure buildings are embedded type, external type and exposed type, and the exposed type is more convenient for on-site installation and positioning. It should be noted that the stiffness of the column base is realized by the elastic or plastic deformation of the base plate. Therefore, in the design, it should be considered that the limit value of the story drift angle should have a certain margin, and the bending moment at the top of the column caused by the downward movement of the bending moment reacts on the bending point of the bottom steel column.

3. Floor design

Steel structure building has precast floor, cast-in-place floor, composite floor and so on. If precast slabs are used, floor joint cracking due to temperature variation and load distribution should be considered. In addition, in the floor design, attention should be paid to avoid one-way centralized layout, and try to form a two-way load-bearing structure.

4. Beam column rigid connection design.

Conventional design method or full section bending design method can be used to calculate the beam column rigid connection in steel structure buildings. When the bending capacity of steel beam flange is more than 70% of the total section capacity, the conventional design method can be used. If it is less than 70%, full section bending design method shall be adopted.

There are many factors to be considered in the design of steel structure buildings, and each link is very important.

Copyright:佛山市勝邦鋼結構有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號
主站蜘蛛池模板: 在线播放日本爽快片 | 日韩国产欧美在线观看一区二区 | 字幕网资源站中文字幕 | 猫咪官方最新版网址 | 亚洲处破女网站 | 欧美aav| 四虎精品久久久久影院 | 色爱阁| 三级主播| 99久久国产综合色 | julia ann多人pk| 日本视频一区二区 | chinese基友gay勾老师 | 孟狐狸视频199vip全部视频 | 一本大道香蕉在线 观看 | 日本女人bbb| 中文字幕欧美在线观看 | 调教女同| 免费看美女下面啪啪流水 | 中国帅哥gary | 中国人与人69xxx | 人人人人草 | 男人天堂成人 | 亚洲国产精品高清在线一区 | freed孕妇pregnant临盆 | 日韩欧美视频一区 | 日本一本二本在线观看 | 日韩在线观看一区二区三区 | 日韩精选 | 中国hd高清xxxx | 12至16末成年毛片 | free性张柏芝 | 日韩欧美国产在线观看 | 久久香蕉国产线看观看精品蕉 | 日韩a级毛片 | 久久国产午夜精品理论篇小说 | 日韩黄色一级视频 | 一级毛片视频 | 色噜噜狠狠一区二区 | 老司机观看精品一区二区 | 日韩精品一 |